Share
Add to compare

PBT TV4 240 S DSM Additive Manufacturing

Properties:
Filler glass fiber reinforced material 20% filler by weight
Product Description
Certificates(0)
Datasheet

Product Description

Properties:Filler | glass fiber reinforced material | 20% | filler by weight

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength23°CISO 179/1eA9.0kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA9.0kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU50kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU50kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.75mmIEC 60695-11-10,-20V-2
UL flame retardant rating1.5mmIEC 60695-11-10,-20V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile strainBreakISO 527-22.5%
tensile strengthBreakISO 527-2110MPa
Tensile modulusISO 527-28500MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Linear coefficient of thermal expansionTDISO 11359-28E-05cm/cm/°C
Linear coefficient of thermal expansionMDISO 11359-24E-05cm/cm/°C
Melting temperatureISO 11357-3225°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A210°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B220°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateTDISO 294-41.7%
Melt Volume Flow Rate (MVR)250°C/2.16kgISO 113323.0cm³/10min
Water absorption rateEquilibrium,23°C,50%RHISO 620.15%
densityISO 11831.61g/cm³
Shrinkage rateMDISO 294-40.60%
Water absorption rateSaturation,23°CISO 620.30%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Relative permittivity1MHzIEC 602503.70
Relative permittivity100HzIEC 602503.90
Dielectric strengthIEC 60243-127kV/mm
Volume resistivityIEC 60093>1.0E+15ohms·cm
Compared to the anti leakage trace indexIEC 60112PLC 2
Dissipation factor1MHzIEC 602500.015
Dissipation factor100HzIEC 602502E-03
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.