PA66 HTNFR52G30LX DUPONT USA
37
Form:Granules | Grade:Injection grade
Properties:
Flame retardantGlass fiber reinforced
Typical Applications:
Automotive sectorElectronic fieldElectrical fieldElectrical appliances
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Electronic field | Electrical field | Electrical appliances |
| Properties: | Flame retardant | Glass fiber reinforced |
Certificates
No Data...
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Extreme Oxygen Index | ISO 4589-2 | 37 | % | |
| Hot filament ignition temperature | 3.0mm | IEC 60695-2-13 | 775 | °C |
| 0.75mm | IEC 60695-2-13 | 725 | °C | |
| 0.40mm | IEC 60695-2-13 | 700 | °C | |
| UL flame retardant rating | 1.5mm | IEC 60695-11-10,-20 | V-0 | |
| 0.75mm | IEC 60695-11-10,-20 | V-0 | ||
| 1.5mm | UL 94 | V-0 | ||
| 0.75mm | UL 94 | V-0 | ||
| FMVSS flammability | FMVSS302 | DNI | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 10000 | Mpa | |
| tensile strength | Break | ISO 527-2 | 150 | Mpa |
| Tensile strain | Break | ISO 527-2 | 2.2 | % |
| Bending modulus | ISO 178 | 8700 | Mpa | |
| bending strength | ISO 178 | 230 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | 3.0mm | UL 746 | 140 | °C |
| 1.5mm | UL 746 | 140 | °C | |
| 0.75mm | UL 746 | 140 | °C | |
| 0.40mm | UL 746 | 140 | °C | |
| Melting temperature | ISO 11357-3 | 310 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 283 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ISO 294-4 | 0.30 | % |
| TD | ISO 294-4 | 1.0 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Relative permittivity | 100Hz | IEC 60250 | 4.30 | |
| Dielectric strength | IEC 60243-1 | 33 | KV/mm | |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| Dissipation factor | 1MHz | IEC 60250 | 0.013 | |
| 100Hz | IEC 60250 | 7E-03 | ||
| Relative permittivity | 1MHz | IEC 60250 | 4.00 | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Odor | VDA270 | 3.50 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.