PEEK LUVOCOM® 1105-0797 LEHVOSS Group
Properties:
Filler glass fiber reinforced material
Typical Applications:
Applications in the automotive field aerospace applications engineering accessories textile applications medical and nursing supplies
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Applications in the automotive field | aerospace applications | engineering accessories | textile applications | medical and nursing supplies |
| Properties: | Filler | glass fiber reinforced material |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1fU | 40 | kJ/m² |
| 23°C | ISO 179/1eU | 40 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 12000 | MPa | |
| tensile strength | Break | ISO 527-2 | 145 | MPa |
| Tensile strain | Yield | ISO 527-2 | 2.0 | % |
| Bending modulus | ISO 178 | 10000 | MPa | |
| bending strength | ISO 178 | 210 | MPa | |
| Bending strain | ISO 178 | 2.5 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | MD | DIN 53752 | 2.2E-05 | cm/cm/°C |
| Continuous use temperature | UL 746B | 250 | °C | |
| Maximum operating temperature | ShortTerm | 280 | °C | |
| thermal conductivity | DIN 52612 | 0.40 | W/m/K | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C,24hr | <0.10 | % | |
| density | ISO 1183 | 1.55 | g/cm³ | |
| Shrinkage rate | DIN 16901 | 0.30to0.70 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| insulation resistance | IEC 60167 | >1.0E+12 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.