Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 179/1eU45kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU45kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA7.0kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA7.0kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
Flammability level0.75mmIEC 60695-11-10,-20V-2
Flammability level1.5mmIEC 60695-11-10,-20V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strengthBreakISO 527-2110MPa
Tensile modulusISO 527-28500MPa
Tensile strainBreakISO 527-22.5%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Melting temperatureISO 11357-3225°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A210°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B220°C
Linear coefficient of thermal expansionTDISO 11359-28E-05cm/cm/°C
Linear coefficient of thermal expansionMDISO 11359-24E-05cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Water absorption rateEquilibrium,23°C,50%RHISO 620.15%
Water absorption rateSaturation,23°CISO 620.30%
densityISO 11831.62g/cm³
Melt Volume Flow Rate (MVR)250°C/2.16kgISO 113323.0cm³/10min
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Compared to the anti leakage trace indexIEC 60112PLC 2
Dissipation factor1MHzIEC 602500.015
Dissipation factor100HzIEC 602502E-03
Relative permittivity1MHzIEC 602503.70
Relative permittivity100HzIEC 602503.90
Dielectric strengthIEC 60243-127kV/mm
Volume resistivityIEC 60093>1.0E+15ohms·cm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.