PBT LW9320 DUPONT USA
106
Form:Granules | Grade:Injection grade
Properties:
Low warpageFiller: Glass fiber reinfAnti warpingGood surface performance 20%20%Filler by weight
Typical Applications:
Electronic and electrical componentsAutomotive ApplicationsIndustrial applicationsIndustrial applicationsBox/Shell/Cover/SetAutomotive Applications
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electronic and electrical components | Automotive Applications | Industrial applications | Industrial applications | Box/Shell/Cover/Set | Automotive Applications |
| Properties: | Low warpage | Filler: Glass fiber reinf | Anti warping | Good surface performance | 20% | 20% | Filler by weight |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 8.5 | kJ/m² |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 45 | kJ/m² |
| 23°C | ISO 179/1eU | 50 | kJ/m² | |
| Impact strength of cantilever beam gap | -40°C | ISO 180/1A | 7.0 | kJ/m² |
| -30°C | ISO 180/1A | 7.0 | kJ/m² | |
| 23°C | ISO 180/1A | 7.0 | kJ/m² | |
| Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 8.0 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| FMVSS flammability | FMVSS302 | B | ||
| UL flame retardant rating | 1.5mm | IEC 60695-11-10,-20 | HB | |
| 0.75mm | IEC 60695-11-10,-20 | HB | ||
| 1.5mm | UL 94 | HB | ||
| 0.75mm | UL 94 | HB | ||
| Burning rate | 1.00mm | ISO 3795 | 30 | mm/min |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23 ℃, Type 1, Notch A | ISO 180 | 7 | KJ/m |
| -40 ℃, Type 1, Notch A | ISO 180 | 7 | KJ/m | |
| Charpy Notched Impact Strength | 23 °C, Type 1, Edgewise, Notch A | ISO 179 | 8.5 | KJ/m |
| Impact strength of simply supported beam without notch | 23 ℃, Type 1, Edgewise | ISO 179 | 55 | KJ/m |
| Bending modulus | 23℃ | ISO 178 | 6100 | MPa |
| Tensile modulus | 23℃ | ISO 527-1 | 7400 | MPa |
| Tensile strain | Break | ISO 527-1 | 2.7 | % |
| Tensile stress | 23℃,Break | ISO 527-1 | 120 | MPa |
| Tensile modulus | ISO 527-2 | 7500 | Mpa | |
| tensile strength | Break | ISO 527-2 | 120 | Mpa |
| Tensile strain | Break | ISO 527-2 | 2.5 | % |
| Bending modulus | ISO 178 | 7000 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.750 mm | UL94 | HB | |
| Hot deformation temperature | 1.80 Mpa,Unannealed | ISO 75A-1 | 180 | ℃ |
| Melting temperature | ISO 3146 | 220 | ℃ | |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 1E-04 | cm/cm/°C |
| UL flame retardant rating | 3.00 mm | UL94 | HB | |
| 1.50 mm | UL94 | HB | ||
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 175 | °C |
| Glass transition temperature | ISO 11357-2 | 110 | °C | |
| Melting temperature | ISO 11357-3 | 220 | °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 3E-05 | cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.35 | ||
| Shrinkage rate | Flow | ISO 294-4 | 0.4 | % |
| Across Flow | ISO 294-4 | 0.65 | % | |
| density | ISO 1183 | 1.34 | g/cm³ | |
| MediumDensity | 1.17 | g/cm³ | ||
| Shrinkage rate | MD | ISO 294-4 | 0.40 | % |
| Water absorption rate | Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.30 | % |
| Stickiness | ISO 307 | 120 | cm³/g | |
| Melt Volume Flow Rate (MVR) | 250°C/5.0kg | ISO 1133 | 15.0 | cm3/10min |
| Shrinkage rate | TD | ISO 294-4 | 0.70 | % |
| Top out temperature | 170 | °C | ||
| SpecificHeatCapacity of Melt | 1900 | J/kg/°C | ||
| ThermalConductivityofMelt | 0.24 | W/m/K | ||
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Odor | VDA270 | 3.50 | ||
| EmissionofOrganicCompounds | VDA277 | 130 | µgC/g |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.