Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength-30°CISO 179/1eA无断裂
Charpy Notched Impact Strength23°CISO 179/1eA无断裂
Impact strength of cantilever beam gap-30°CISO 180/1A无断裂
Impact strength of cantilever beam gap-20°CISO 180/1A无断裂
Impact strength of cantilever beam gap23°CISO 180/1A无断裂
flammabilityTest ConditionTest MethodTest ResultTest Unit
Flammability level1.5mmIEC 60695-11-10,-20HB
Flammability level3.0mmIEC 60695-11-10,-20HB
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strength50%StrainISO 527-27.00MPa
tensile strength100%StrainISO 527-28.00MPa
Nominal tensile fracture strainISO 527-2530%
tensile strength5.0%StrainISO 527-22.20MPa
tensile strength10%StrainISO 527-24.00MPa
Tensile modulusISO 527-244.0MPa
tensile strengthBreakISO 527-216.0MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Melting temperatureISO 11357-3212°C
Linear coefficient of thermal expansionMDISO 11359-21.5E-04cm/cm/°C
Linear coefficient of thermal expansionTDISO 11359-21.5E-04cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 11831.16g/cm³
Water absorption rateSaturation,23°CISO 627.0%
Water absorption rateEquilibrium,23°C,50%RHISO 620.40%
Melt Volume Flow Rate (MVR)230°C/2.16kgISO 113331.5cm³/10min
Shrinkage rateTDISO 294-41.8%
Shrinkage rateMDISO 294-41.6%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Dielectric strengthIEC 60243-120kV/mm
Relative permittivity100HzIEC 602504.70
Relative permittivity1MHzIEC 602504.40
Dissipation factor100HzIEC 602500.031
Dissipation factor1MHzIEC 602500.081
Compared to the anti leakage trace indexIEC 60112PLC 0
Volume resistivityIEC 600931E+14ohms·cm
hardnessTest ConditionTest MethodTest ResultTest Unit
Shore hardnessShoreD,3SecISO 86832
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.