PC+PBT 9KF23500 HI 4Plas
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | -20°C | ISO 180/1A | 8.0 | kJ/m² |
| 23°C | ISO 180/1A | 12 | kJ/m² | |
| Suspended wall beam without notch impact strength | -30°C | ISO 180/1U | 无断裂 | |
| 23°C | ISO 180/1U | 无断裂 | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | V-0 | |
| 3.2mm | UL 94 | V-0 | ||
| Hot filament ignition temperature | 2.0mm | IEC 60695-2-13 | 960 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C | ISO 527-2/5 | 2100 | MPa |
| tensile strength | Break,23°C | ISO 527-2/5 | 45.0 | MPa |
| Tensile strain | Break,23°C | ISO 527-2/5 | 20 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 130 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 60.0 | °C | |
| Vicat softening temperature | ISO 306/B | 160 | °C | |
| Melting temperature | DSC | 220to230 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.34 | g/cm³ | |
| melt mass-flow rate | 270°C/2.16kg | ISO 1133 | 60 | g/10min |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.10 | % |
| water content | ISO 960 | <1000 | ppm | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 2 | ||
| Surface resistivity | IEC 60093 | 1E+15 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.