PBT 1200M TORAY JAPAN
41
Form:Granules | Grade:Injection grade
Properties:
transparentstandard
Typical Applications:
Bottle capElectric wireCableFood service sector
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Bottle cap | Electric wire | Cable | Food service sector |
| Properties: | transparent | standard |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| tensile strength | ISO 527-1/-2 | 58 | MPa | |
| bending strength | ISO 178 | 83 | MPa | |
| Bending modulus | ISO 178 | 2.4 | Gpa | |
| Charpy Notched Impact Strength | ISO 179/1eA | 5.1 | KJ/m | |
| Bending modulus | ISO 178 | 2400 | Mpa | |
| bending strength | ASTM D790 | 82.0 | Mpa | |
| ISO 178 | 83.0 | Mpa | ||
| tensile strength | Yield | ASTM D638 | 54.0 | Mpa |
| ISO 527-2 | 58.0 | Mpa | ||
| elongation | Break | ASTM D638 | >150 | % |
| Tensile strain | Break | ISO 527-2 | 120 | % |
| Bending modulus | ASTM D790 | 2500 | Mpa | |
| Charpy Notched Impact Strength | ASTM D256/ISO 179 | 5.1 | kg·cm/cm(J/M)ft·lb/in | |
| Elongation at Break | ASTM D638/ISO 527 | 120 | % | |
| tensile strength | ASTM D638/ISO 527 | 58 | kg/cm²(MPa)[Lb/in²] | |
| Bending modulus | ASTM D790/ISO 178 | 2.4 | kg/cm²(MPa)[Lb/in²] | |
| bending strength | ASTM D790/ISO 178 | 83 | kg/cm²(MPa)[Lb/in²] | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL94 | HB | ||
| Melting temperature | 224 | °C | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 250°C/1.0kg | ISO 1133 | 8.7 | g/10min |
| Melt Volume Flow Rate (MVR) | 250°C/2.16kg | ISO 1133 | 16.0 | cm3/10min |
| Viscosity value | 0.5%OCP | Internal Method | 1.23 | cm³/g |
| density | ASTM D792/ISO 1183 | 1.315 | ||
| melt mass-flow rate | ASTM D1238/ISO 1133 | 224 | g/10min |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.