Share
Add to Compare

PPA HTN53G50LRHF GY791 DUPONT USA

12

Form:Granules | Grade:Injection grade

Properties:
Flame retardantGlass fiber reinforcedThermal stabilityHigh temperature resistan
Typical Applications:
Food containers
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Food containers
Properties:Flame retardant | Glass fiber reinforced | Thermal stability | High temperature resistan

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gapDry,23℃ISO 180/1A236°C
Impact strength of cantilever beam gapDry,-40℃ISO 180/1A15kJ/m²
Charpy Notched Impact StrengthDry,23℃ISO 179/1eA95kJ/m²
Charpy Notched Impact StrengthDryISO 179/1eA15kJ/m²
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Poisson's ratioDryISO 527-1/-214
Tensile modulusDryISO 527-1/-216500 Mpa
Tensile modulusConditioISO 527-1/-216300 Mpa
Bending modulusDryISO 17815000 Mpa
Elongation at BreakDryISO 527-1/-22.8%
Elongation at BreakConditioISO 527-1/-23.2%
tensile strengthDry,BreakISO 527-1/-2250Mpa
tensile strengthConditione,BreakISO 527-1/-2215 Mpa
thermal propertiesTest ConditionTest MethodTest ResultTest Unit
Melting temperatureISO 11357-1/-3260°C
Linear coefficient of thermal expansion-40-23°C,Across FlowISO 11359-1/-255E-6/K
Linear coefficient of thermal expansionAcross FlowISO 11359-1/-255E-6/K
Linear coefficient of thermal expansion-40-23°C,FlowISO 11359-1/-217E-6/K
Linear coefficient of thermal expansionFlowISO 11359-1/-214E-6/K
RTI ElecUL 746B65°C
RTI ElecUL 746B65°C
RTI ElecUL 746B65°C
RTI ImpUL 746B65°C
RTI ImpUL 746B65°C
RTI ImpUL 746B65°C
combustion performanceTest ConditionTest MethodTest ResultTest Unit
UL flame retardant ratingHBUL 940.75mm
UL flame retardant ratingHBUL 941.5 mm
Limiting Oxygen Index (LOI)ISO 4589-1/-227%
FMVSS combustion rateFMVSS 302B -
Burning rate1mmISO 379525mm/min
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateDryISO 294-40.4%
Shrinkage rateDry,FlowISO 294-40.2%
Electrical PropertyTest ConditionTest MethodTest ResultTest Unit
Volume resistivityIEC 6009310000000000000Ohm-m
Compared to the Leakage Traceability Index (CTI)IEC 60112600 -
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.