PPA HTV-4H1 EMS-CHEMIE SWITZERLAND
23
Form:Granules | Grade:Injection grade
Properties:
Low warpageChemical resistance
Typical Applications:
household electrical appliancesAutomotive interior parts
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | household electrical appliances | Automotive interior parts |
| Properties: | Low warpage | Chemical resistance |
Certificates
No Data...
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | 0.8mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2/1 | 14000 | Mpa | |
| tensile strength | Break | ISO 527-2/5 | 210 | Mpa |
| Tensile strain | Break | ISO 527-2/5 | 2.0 | % |
| Charpy Notched Impact Strength | 23℃ | ISO 179/1eA | 8 | kJ/m² |
| 23℃ | ISO 179/1eU | 70 | kJ/m² | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 0.000050 | cm/cm/ ℃ |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 280 | °C |
| 8.0MPa,Unannealed | ISO 75-2/C | 175 | °C | |
| Linear coefficient of thermal expansion | Flow | ISO 11359-2 | 0.000015 | cm/cm/ ℃ |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | Across Flow | ISO 294-4 | 0.55 | % |
| Flow | ISO 294-4 | 0.1 | % | |
| Water absorption rate | 23℃ | ISO 62 | 3.5 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1E+12 | ohms | |
| Volume resistivity | IEC 60093 | 1E+13 | ohms*cm | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| Dielectric strength | IEC 60246-1 | 35 | KV/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.