PA6 9B22115 XHFR1 4Plas
Properties:
Filler glass fiber reinforced material 15% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 15% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 65 | kJ/m² |
| -30°C | ISO 180/1U | 60 | kJ/m² | |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 9.0 | kJ/m² |
| -30°C | ISO 180/1A | 8.0 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.750mm | UL 94 | V-0 | |
| Hot filament ignition temperature | 2.00mm | IEC 60695-2-13 | 825 | °C |
| Burning wire flammability index | 2.00mm | IEC 60695-2-12 | 960 | °C |
| UL flame retardant rating | 1.60mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break,23°C | ISO 527-2/5 | 2.5 | % |
| tensile strength | Break,23°C | ISO 527-2/5 | 100 | MPa |
| Tensile modulus | 23°C | ISO 527-2/5 | 7500 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357 | 223 | °C | |
| Vicat softening temperature | ISO 306/B | 210 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| water content | ISO 960 | <2000 | ppm | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 1.7 | % |
| Shrinkage rate | MD | 0.30 | % | |
| TD | 0.90 | % | ||
| density | ISO 1183 | 1.53 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+13 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.