Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | 0.2-0.9 % | ||
density | ASTM D-792 | 1.63 | |
Water absorption rate | ASTM D-570 | 0.03 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTM D-638 | 130 MPa | |
Impact strength of cantilever beam gap | Notched | ASTM D-256 | 0.08 KJ/M |
Rockwell hardness | ASTM D-785 | 119 R | |
bending strength | ASTM D-790 | 175 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Breakdown voltage strength | ASTM D-149 | 32 KV/mm | |
Volume resistivity | ASTM D-257 | 3.2 Ω.cm | |
dielectric constant | ASTM D-150 | 3.6 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Linear coefficient of thermal expansion | ASTM D-696 | 3 1e-5cm/cm/℃ | |
Heat distortion temperature | ASTM D-648 | 210 ℃ | |
combustibility | UL 94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.