Share
Add to Compare

PC/ABS C2950-701 SABIC INNOVATIVE KOREA

222

Form:Granules

Properties:
Flame retardantHigh mobilityHigh impact resistanceHigh temperature resistanheat-resisting
Typical Applications:
Electrical fieldElectronic fieldHousehold appliancesHousehold appliancesAutomotive sector
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Electrical field | Electronic field | Household appliances | Household appliances | Automotive sector
Properties:Flame retardant | High mobility | High impact resistance | High temperature resistan | heat-resisting

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Instrumented dart impact energy 23 ℃ (73 ℉) total energyASTM D376361 J
Instrumented dart impact energy -30 ℃ (-22 ℉) peakASTM D376354 J
Impact strength of cantilever beam gap23℃ASTM D256534J/m
Impact strength of cantilever beam gap30℃ASTM D256160J/m
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Bending modulus2.6 mm/ASTM D7902650Mpa
bending strength2.6 mm/,YieldASTM D790102Mpa
Elongation at BreakType I, 50ASTM D63840
tensile strengthType I, 50,YieldASTM D63862Mpa
thermal propertiesTest ConditionTest MethodTest ResultTest Unit
thermal conductivityASTM C 1770.2 W/m-°C
Linear coefficient of thermal expansion-30°C to 3,Across FlowASTM E83172E-6/°C
Linear coefficient of thermal expansion-30°C to 3,FlowASTM E83172E-6/°C
RTI ImpUL 746B85°C
RTI ElecUL 746B85°C
RTI ImpUL 746B85°C
Vicat softening temperatureRate B/50ASTM D152585°C
combustion performanceTest ConditionTest MethodTest ResultTest Unit
Limiting Oxygen Index (LOI)ASTM D 286332%
UL fire rating 5VBUL 942.49mm
UL fire rating VUL 941.5mm
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
melt mass-flow rateASTM D123810g/10min
Water absorption rate24 hoursASTM D5700.1
Water absorption rateflow, 3.2ASTM D5700.4
Shrinkage ratexflow, 3.2Internal0.4-0.6
Shrinkage rateflow, 3.2Internal0.4-0.8
Electrical PropertyTest ConditionTest MethodTest ResultTest Unit
Surface resistivityASTM D25710000000000000000Ohm
Volume resistivityASTM D257100000000000000000ohm-cm
Dielectric constantASTM D 150
Dielectric constantASTM D 150
Dissipation factorASTM D 15050E-4
Dissipation factorASTM D 15049E-4
Compared to the Leakage Traceability Index (CTI)UL 746APLC_0
Dielectric strengthin oil, 3.2ASTM D14919.5kV/mm
Arc resistanceASTM D495PLC_6
High voltage arc tracing rateUL 746APLC 2
Hot wire ignition (HWI)UL 746APLC_1
High current arc ignition (HAI)UL 746APLC_0
hardnessTest ConditionTest MethodTest ResultTest Unit
Hardness (Rockwell R)ASTM D785123R
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Sourcing & Prices

Selling & Verification

Explore Materials

Price Index

+86 0755 27873515

Room 906, Global Digital Building, No. 9 Gaoxin Middle 3rd Road, Maling Community, Yuehai Subdistrict, Nanshan District, Shenzhen, Guangdong Province, China