PA66 Grilon® TS V0 NA EMS-CHEMIE TAIWAN
5
- Properties:Glass fiber reinforcedThermal stability
- Usages:Automotive ApplicationsProfile
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | kJ/m² | 70 -- |
| 23°C | kJ/m² | 75 |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Flammability level | 1.5mm | V-0 -- | |
| 0.40mm | V-0 -- | ||
| Extreme Oxygen Index | % | 35 -- |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | MPa | 3600 1600 | |
| tensile strength | Yield | MPa | 85.0 50.0 |
| Break | MPa | 75.0 50.0 | |
| Tensile strain | Yield | % | 4.0 |
| Nominal tensile fracture strain | % | 10 >50 |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Linear coefficient of thermal expansion | TD | cm/cm/°C | 9E-05 -- |
| Hot deformation temperature | 0.45MPa,Unannealed | °C | 210 -- |
| 1.8MPa,Unannealed | °C | 70.0 -- | |
| Continuous use temperature | --3 | °C | 100to120 -- |
| --4 | °C | 200 -- | |
| Melting temperature | °C | 260 -- | |
| Linear coefficient of thermal expansion | MD | cm/cm/°C | 7E-05 -- |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | TD | % | 0.80 -- |
| MD | % | 0.70 -- | |
| Water absorption rate | Saturation,23°C | % | 8.0 -- |
| Equilibrium,23°C,50%RH | % | 2.5 -- |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Surface resistivity | ohms | -- 1E+10 | |
| Volume resistivity | ohms·cm | 1E+13 | |
| Dielectric strength | kV/mm | 28 26 | |
| Relative permittivity | 100Hz | 3.00 8.00 | |
| 1MHz | 3.00 | ||
| Dissipation factor | 100Hz | 5E-03 0.15 | |
| 1MHz | 0.015 0.070 | ||
| Compared to the anti leakage trace index | V | -- |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.