Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD3763 | 1.39 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
elongation | Break | ASTMD638 | 1.2 % |
Flexural modulus | | ASTMD790 | 6300 MPa |
bending strength | | ASTMD790 | 95.0 MPa |
Tensile modulus | | ASTMD638 | 6700 MPa |
tensile strength | Break | ASTMD638 | 71.0 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD412 | 53 J/m |
Suspended wall beam without notch impact strength | | ASTMD412 | 180 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | | 0.60 ohms |
Volume resistivity | | | 0.060 ohms·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648 | 100 °C |
RTI | | UL746 | 70.0 °C |
| | ASTMD696 | 3E-05 cm/cm/°C |
thermal conductivity | | ASTMD5470 | 0.59 W/m/K |
RTI Elec | | UL746 | 70.0 °C |
RTI Imp | | UL746 | 70.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.