Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.35 g/cm³ |
Water absorption rate | | ASTM D570 | <1.3 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | M-Scale | ASTM D785 | 105 |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Viscosity | | | 730000 g |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ASTM D790 | >100 MPa |
compressive strength | | ASTM D695 | 255 MPa |
bending strength | | ASTM D790 | >114 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | >67 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | >53 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | | >3000 V |
dielectric strength | | | >40000 V |
relative permittivity | | IEC 60250 | 5.80 |
relative permittivity | | IEC 60250 | 6.00 |
Dissipation Factor | | ASTM D150 | 0.055 |
Dissipation Factor | | ASTM D150 | 0.070 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
TEMPERATURE | | | 125 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.