Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO 62 | 5.5 % |
Water absorption rate | | ISO 62 | 1.2 % |
other | Test Condition | Test Method | Test Result |
---|
characteristic | | | 阻燃增强注塑级 |
purpose | | | 25%玻纤增强.UL94认证.阻燃V-0级.卤素阻燃型。 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Burning wire flammability index | | IEC 60695-2-12 | 960 °C |
Burning wire flammability index | | IEC 60695-2-12 | 960 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 725 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 725 °C |
burning rate | | FMVSS302 | 0.0 mm/min |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO 179/1eU | 65 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 68 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2/1A/1 | 7900 Mpa |
tensile strength | | ISO 527-2/1A/5 | 120 Mpa |
Tensile strain | | ISO 527-2/1A/5 | 3.3 % |
Flexural modulus | | ISO 178 | 6900 Mpa |
bending strength | | ISO 178 | 185 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC 60093 | 1E+12 ohms |
Volume resistivity | | IEC 60093 | 1E+15 ohms·cm |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 1 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/Af | 230 °C |
vicat | | ISO 306/B50 | 240 °C |
melting temperature | | ISO 11357 | 260 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.