physical property | Test Condition | Test Method | Test Result |
---|
Melt volume flow rate | | ISO 1133 | 25 cm3/10min |
Shrinkage rate | | | 0.4 % |
density | | ISO 1183 | 1.6 g/cm³ |
Viscosity value | | ISO 307 | 140 cm³/g |
Water absorption rate | | ISO 62 | 3.7 - 4.3 % |
Water absorption rate | | ISO 62 | 0.70 - 1.10 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-1-2 | 16000 / 12000 Mpa |
Tensile strain | | ISO 527-1-2 | 180 / 130 Mpa |
Tensile creep modulus | | ISO 899-1 | * / 5400 Mpa |
Flexural modulus | | ISO 178 | 13000 / - Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA | 13 / 16 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 11 / - kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eA | 55 / 55 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eA | 50 / - kJ/m² |
Impact strength of cantilever beam gap | | ISO 180-A | 14 / 20 kJ/m² |
handle | Test Condition | Test Method | Test Result |
---|
melting temperature | | ISO 11357-1/-3 | 260 °C |
Melt Temperature | | | 290 - 300 °C |
Temperature | | | 80-90 °C |
Flammable | Test Condition | Test Method | Test Result |
---|
Glow wire combustion index (GWFI) | | IEC 60695-2-12 | 960 °C |
Limiting Oxygen Index | | ISO 4589-1/-2 | 27 % |
Smoke density | | EN ISO 5659-2: 2007 | 184 |
smoke toxicity | | NF X70-100-1/-2 | 0.36 |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | IEC 60250 | 3.6 / 5 |
Dissipation Factor | | IEC 60093 | 1E13 / 1E10 E-4 |
Volume resistivity | | IEC 60093 | /1E10 Ohm*m |
Volume resistivity | | IEC 60112 | 600 ohms |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-1/2 | 250 °C |
Heat distortion temperature | | ISO 75-1/2 | 250 °C |
Linear coefficient of thermal expansion | | ISO 11359-1/-2 | 40-50 E-6/K |
Linear coefficient of thermal expansion | | ISO 11359-1/-2 | 15 - 20 E-6/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.