PC 1800R SABIC INNOVATIVE US
43
Form:Granules | Grade:Injection grade
Properties:
High glossAging resistancewear resistantWeather resistanceThermal stability
Typical Applications:
CastersAutomotive sectorHousehold appliancesElectronic fieldElectrical field
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Casters | Automotive sector | Household appliances | Electronic field | Electrical field |
| Properties: | High gloss | Aging resistance | wear resistant | Weather resistance | Thermal stability |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Refractive index | ASTMD542 | 1.586 | ||
| transmissivity | 2540μm | ASTM D1003 | 88.0to90.0 | % |
| turbidity | 2540μm | ASTM D1003 | <0.80 | % |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Dart impact | 23°C,EnergyatPeakLoad | ASTM D3763 | 65.0 | J |
| -30°C | ISO 180/1U | 无断裂 | ||
| 23°C | ASTMD4812 | 无断裂 | ||
| ISO 180/1A | 70 | kJ/m² | ||
| -30°C | ISO 180/1A | 12 | kJ/m² | |
| 23°C | ASTM D256 | 700 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.50mm | UL 94 | V-2 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| crack | ISO 527-2/50 | >70 | % | |
| 50.0mm span | ASTM D790 | 2300 | Mpa | |
| --7 | ISO 178 | 2300 | Mpa | |
| --8 | ISO 178 | 90.0 | Mpa | |
| crack | ASTM D638 | >70 | % | |
| yield | ISO 527-2/50 | 6.0 | % | |
| ASTM D638 | 6.0 | % | ||
| ISO 527-2/50 | 63.0 | Mpa | ||
| ASTM D638 | 63.0 | Mpa | ||
| --2 | ASTM D638 | 2350 | Mpa | |
| Yield, 50.0mm span | ASTM D790 | 90.0 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| 1.8MPa, unannealed, 3.20mm | ASTM D648 | 124 | °C | |
| 0.45MPa, unannealed, 64.0mm span | ISO 75-2/Bf | 135 | °C | |
| 0.45MPa, unannealed, 3.20mm | ASTM D648 | 135 | °C | |
| 1.8MPa, unannealed, 64.0mm span of | ISO 75-2/Af | 124 | °C | |
| Vicat softening temperature | ISO 527-3/1 | 141 | °C | |
| Ball Pressure Test | 125°C | IEC 60695-10-2 | Pass | |
| -40 to 95 ° C | ASTME831 | 7E-05 | cm/cm/°C | |
| 23 to 80 ° C | ISO 11359-2 | 7E-05 | cm/cm/°C | |
| thermal conductivity | DENKA Method | 0.20 | W/m/K | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Balance, 23 ° C | ASTM D570 | 0.35 | % | |
| Saturation, 23 ° C | ISO 62 | 0.35 | % | |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.50-0.70 | % |
| MD:--1 | Internal Method | 0.50-0.70 | % | |
| Melt Volume Flow Rate (MVR) | 300°C/1.2kg | ISO 1133 | 17.0 | cm3/10min |
| melt mass-flow rate | 300°C/1.2kg | ASTM D1238 | 18 | g/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 60Hz | ASTMD150 | 1E-03 | |
| 1MHz | ASTMD150 | 0.010 | ||
| Volume resistivity | ASTMD257 | >1.0E+15 | ohms·cm | |
| Dielectric strength | 1.60mm | ASTM D2863 | 27 | KV/mm |
| Dielectric constant | 60Hz | ASTMD150 | 3.00 | |
| 1MHz | ASTMD150 | 3.00 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Hardness (Rockwell R) | ISO 2039-2 | 120 | ||
| ASTM D785 | 120 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.