PC II 55D DSM Additive Manufacturing
Typical Applications:
Medical and nursing supplies
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Medical and nursing supplies |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| bending strength | 5.0%Strain | ASTM D790 | 3.52 | MPa |
| Bending modulus | ASTM D790 | 95.1 | MPa | |
| elongation | Break | ASTM D1708 | 370 | % |
| Taber abraser | 1000Cycles,1000g,H-18Wheel | ASTM D1044 | 11.0 | mg |
| Friction coefficient | Itself - Dynamic | ASTM D1894 | 0.46 | |
| tensile strength | 300%Strain | ASTM D1708 | 49.0 | MPa |
| 100%Strain | ASTM D1708 | 18.1 | MPa | |
| 50%Strain | ASTM D1708 | 13.6 | MPa | |
| Break | ASTM D1708 | 61.8 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ASTME1356 | 180 | °C | |
| Vicat softening temperature | ASTM D1525 | 107 | °C | |
| Glass transition temperature | ASTME1356 | 1.00 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| average molecular weight | Internal Method | 231000 | Mw | |
| Water absorption rate | Saturation | ASTM D750 | 0.54 | % |
| Shrinkage rate | MD | ASTM D955 | 0.80to2.3 | % |
| melt mass-flow rate | ASTM D1238 | 35 | g/10min | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | 60Hz | ASTM D150 | 3.71 | |
| Dielectric strength | ASTM D149 | 17 | kV/mm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD | ASTM D2240 | 56 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.