PA12 L 20 H FR EMS-CHEMIE SWITZERLAND
56
Form:Granules | Grade:Flame retardant grade
Properties:
High temperature resistanHigh impact resistance
Typical Applications:
Fitness equipmentElectronic and electrical components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Fitness equipment | Electronic and electrical components |
| Properties: | High temperature resistan | High impact resistance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23℃23°C | ISO 179/1eU | 无断裂 | |
| -30℃-30°C | ISO 179/1eU | 无断裂 | ||
| Charpy Notched Impact Strength | 23℃23°C | ISO 179/1eA | 5 | kJ/m² |
| -30℃-30°C | ISO 179/1eA | 6 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | YieldYield | ISO 527-2 | 5 | % |
| Nominal tensile fracture strain | ISO 527-2 | > 50 | % | |
| tensile strength | BreakBreak | ISO 527-2 | 40 | Mpa |
| YieldYield | ISO 527-2 | 50 | Mpa | |
| Tensile modulus | ISO 527-2 | 1900 | Mpa | |
| Shore hardness | Shore D,15 SecShore D,15 Sec | ISO 868 | -- | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | TDTransverse | ISO 11359-2 | 0.00012 | 1/℃ |
| MDFlow | ISO 11359-2 | 0.000090 | 1/℃ | |
| Melting temperature | ISO 11357-3 | 178 | °C | |
| Continuous use temperature | ---- 44 | Internal Method | 150 | °C |
| ---- 33 | ISO 2578 | 90.0 to 110 | °C | |
| Hot deformation temperature | 1.8 MPa,Unannealed264 psi, Unannealed | ISO 75-2/A | 50 | °C |
| 0.45 MPa,Unannealed66 psi, Unannealed | ISO 75-2/B | 130 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23℃,50% RHEquilibrium, 73°F, 50% RH | ISO 62 | 0.7 | % |
| Saturation,23℃Saturation, 73°F | ISO 62 | 1.4 | % | |
| Shrinkage rate | MDFlow | ISO 294-4 | 0.6 | % |
| TDAcross Flow | ISO 294-4 | 0.8 | % | |
| density | ISO 1183 | 1.05 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | IEC 60243-1 | -- | KV/mm | |
| Volume resistivity | IEC 60093 | -- | ohms·cm | |
| Surface resistivity | IEC 60093 | -- | ohms | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | UL 94 | V-2 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.