PA66 VAMPSTAT Y 00U 06 V0 26 SC2 ST VAMP TECH ITALY
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | ISO 180 | 40 | kJ/m² | |
| Impact strength of cantilever beam gap | ISO 180/A | 5.0 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 960 | °C |
| UL flame retardant rating | 3.2mm | UL 94 | V-0 | |
| 1.6mm | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | Break | ASTM D638 | 5.0 | % |
| tensile strength | Yield | ASTM D638 | 30.0 | MPa |
| Tensile modulus | ASTM D638 | 1800 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ASTM D15252 | 120 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648A | 70.0 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.30 | g/cm³ | |
| Shrinkage rate | TD | ASTM D955 | 1.6 | % |
| MD | ASTM D955 | 1.7 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | ASTM D257 | 1E+06 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.