PBT 4521-1001 SABIC INNOVATIVE SHANGHAI
85
Form:Granules
Properties:
Flame retardantGlass fiber reinforcedHigh mobilityChemical resistanceFiller: Glass fiber reinf20%Filler by weight20%Filler by weight
Typical Applications:
Electrical fieldElectronic fieldArchitectural application fieldPlastic bagLighting applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical field | Electronic field | Architectural application field | Plastic bag | Lighting applications |
| Properties: | Flame retardant | Glass fiber reinforced | High mobility | Chemical resistance | Filler: Glass fiber reinf | 20% | Filler by weight | 20% | Filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ASTM D4812 | 480 | J/m |
| 23°C | ASTM D256 | 43 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.75mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ASTM D638 | 3520 | Mpa | |
| bending strength | Break,50.0mmSpan | ASTM D790 | 138 | Mpa |
| Bending modulus | 50.0mmSpan | ASTM D790 | 4960 | Mpa |
| elongation | Break | ASTM D638 | 2.5 | % |
| Yield | ASTM D638 | 2.4 | % | |
| tensile strength | Break | ASTM D638 | 91.0 | Mpa |
| Yield | ASTM D638 | 89.6 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Str | UL 746 | 130 | °C | |
| RTI Imp | UL 746 | 130 | °C | |
| RTI Elec | UL 746 | 130 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed,3.20mm | ASTM D648 | 205 | °C |
| 0.45MPa,Unannealed,3.20mm | ASTM D648 | 219 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.30-0.70 | % |
| TD:3.20mm | Internal Method | 0.60-0.90 | % | |
| density | ASTM D792 | 1.53 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot wire ignition | HWI | UL 746 | PLC 0 | |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 4 | |
| High arc combustion index | HAI | UL 746 | PLC 0 | |
| Arc resistance | ASTM D495 | PLC 5 | ||
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 2 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.