PPS 6565A6 JAPAN POLYPLASTIC
164
Form:Granules | Grade:Injection grade
Properties:
transparentHigh temperature resistanHigh mobilityFlame retardantGlass fiber reinforced
Typical Applications:
Electronic fieldElectrical field
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electronic field | Electrical field |
| Properties: | transparent | High temperature resistan | High mobility | Flame retardant | Glass fiber reinforced |
Certificates

Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| characteristic | 低温模具.良好树脂间粘接性 | |||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ASTM D790/ISO 178 | 18200 | kg/cm²(MPa)[Lb/in²] | |
| bending strength | ASTM D790/ISO 178 | 165 | kg/cm²(MPa)[Lb/in²] | |
| tensile strength | ASTM D638/ISO 527 | 125 | kg/cm²(MPa)[Lb/in²] | |
| Elongation at Break | ASTM D638/ISO 527 | 1 | % | |
| Impact strength of cantilever beam gap | ASTM D256/ISO 179 | 4.5 | kg·cm/cm(J/M)ft·lb/in | |
| bending strength | ISO 178 | 165 | Mpa | |
| Bending modulus | ISO 178 | 18200 | Mpa | |
| Tensile strain | Break | ISO 527-2 | 1.0 | % |
| tensile strength | ISO 527-2 | 125 | Mpa | |
| Elongation at Break | ASTM D638/ISO 527 | 1 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | TD | Internal Method | 3E-05 | cm/cm/°C |
| MD | Internal Method | 1E-05 | cm/cm/°C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 275 | °C |
| Combustibility (rate) | UL 94 | V-0 | ||
| Vicat softening temperature | ASTM D1525/ISO R306 | 275 | ℃(℉) | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C,24hr | ISO 62 | 0.010 | % |
| Melt viscosity | 310°C,1000sec^-1 | ISO 11443 | 280000 | mPa·s |
| density | ASTM D792/ISO 1183 | 1.96 | ||
| Water absorption rate | ASTM D570/ISO 62 | 0.01 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257/IEC 60093 | 2.0 x 10^ 16 | Ω.cm | |
| Relative permittivity | 1MHz | IEC 60250 | 5.40 | |
| 1kHz | IEC 60250 | 5.40 | ||
| Dielectric strength | 3.00mm | IEC 60243-1 | 16 | KV/mm |
| Volume resistivity | IEC 60093 | 2E+16 | ohms·cm | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 3 | ||
| Dissipation factor | 耐电弧性 | IEC 60250 | 189 | sec |
| 1MHz | IEC 60250 | 5E-03 | ||
| 1kHz | IEC 60250 | 0.013 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Scale | ISO 2039-2 | 95 | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| ColourNumber | HF2000/HD9050 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.