physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO 62 | 0.20 % |
Water absorption - Ejil, 65% RH | | 内部方法 | 1.9 % |
Shrinkage rate | | 内部方法 | 0.10-0.40 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
Limiting Oxygen Index | | ISO 4589-2 | 25 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 11500 Mpa |
tensile strength | | ISO 527-2 | 190 Mpa |
Tensile strain | | ISO 527-2 | 2.0 % |
Flexural modulus | | ISO 178 | 11500 Mpa |
bending strength | | ISO 178 | 285 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ASTM D256 | 460 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | IEC 60093 | 1E+13 ohms·cm |
dielectric strength | | IEC 60243-1 | 30 KV/mm |
dielectric constant | | IEC 60250 | 3.90 |
Dissipation Factor | | IEC 60250 | 0.010 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 1 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/A | 230 °C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 1.8E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.