Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTMD792 | 1.05 g/cm³ | |
Shrinkage rate | ASTMD995 | 0.55 % | |
ASTMD1238 | 15.00 g/10min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
elongation at break | ASTMD638 | 10 % | |
Flexural modulus | ASTMD790 | 2700 MPa | |
Impact strength of cantilever beam gap | ASTMD256 | 150 J/m | |
tensile strength | ASTMD638 | 46 MPa |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|---|---|---|
fire rating | UL-94 | 1.60mm HB | |
UL-94 | 3.20mm HB | ||
Relative temperature of heating wire | IEC60695-2-13 | 650 °C |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ASTM1525 | 115 °C | |
ASTM1525 | 106 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.