PA6 ADDINYL B2 E ADDIPLAST FRANCE
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | kJ/m² | 3.0 | 10 | |
| Impact strength of simply supported beam without notch | 无断裂 | |||
| Charpy Notched Impact Strength | kJ/m² | 3.0 | 10 | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Hot filament ignition temperature | °C | 960 | -- | |
| UL flame retardant rating | 1.6mm | V-2 | -- | |
| Extreme Oxygen Index | % | 30 | -- | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | MPa | 3000 | 1000 | |
| Tensile strain | Break | % | 10 | 30 |
| tensile strength | Break | MPa | 60.0 | 45.0 |
| Yield | MPa | 75.0 | 40.0 | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | °C | 220 | -- | |
| Hot deformation temperature | 1.8MPa,Unannealed | °C | 65.0 | -- |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | g/cm³ | 1.17 | -- | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | ohms | 1E+14 | 1E+12 | |
| Compared to the anti leakage trace index | SolutionA | V | PLC 0 | |
| Dielectric strength | kV/mm | 26 | -- | |
| Volume resistivity | ohms·cm | 1E+15 | 1E+12 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD | 83 | 77 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.