Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Melt volume flow rate | | ISO1133 | 20.0 cm3/10min |
flammability | Test Condition | Test Method | Test Result |
---|
Burning wire flammability index | | IEC60695-2-12 | 700 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 725 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 725 °C |
burning rate | | ISO3795 | 20 mm/min |
Flammability level | | IEC60695-11-10,-20 | HB |
Flammability level | | IEC60695-11-10,-20 | HB |
Burning wire flammability index | | IEC60695-2-12 | 700 °C |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO179/1eU | 45 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 30 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2/1A/1 | 6500 Mpa |
Tensile stress | | ISO527-2/1A/5 | 96.0 Mpa |
Tensile strain | | ISO527-2/1A/5 | 2.6 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
CTI | | IEC60112 | 250 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/Bf | 210 °C |
| | ISO75-2/Af | 172 °C |
vicat | | ISO306/A50 | 205 °C |
vicat | | ISO306/B50 | 145 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.