PA6 B30SF LANXESS BELGIUM
168
Form:Granules
Properties:
Heat aging
Typical Applications:
Automotive componentsInstrumentationElectronic and electrical enclosureIndustrial applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive components | Instrumentation | Electronic and electrical enclosure | Industrial applications |
| Properties: | Heat aging |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | 23℃23°C | ISO 180/1U | 120 | kJ/m² |
| -30℃-30°C | ISO 180/1U | 100 | kJ/m² | |
| Impact strength of cantilever beam gap | 23℃23°C | ISO 180-1A | < 10 | kJ/m² |
| -30℃-30°C | ISO 180-1A | < 10 | kJ/m² | |
| Impact strength of simply supported beam without notch | 23℃23°C | ISO 179/1eU | 150 | kJ/m² |
| -30℃-30°C | ISO 179/1eU | 130 | kJ/m² | |
| Charpy Notched Impact Strength | 23℃23°C | ISO 179/1eA | < 10 | kJ/m² |
| -30℃-30°C | ISO 179/1eA | < 10 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | 23℃23°C 55 | ISO 178-A | 110 | Mpa |
| 3.50% Strain,23℃3.5% Strain, 23°C | ISO 178-A | 100 | Mpa | |
| Bending modulus | 23℃23℃5 | ISO 178-A | 3200 | Mpa |
| Nominal tensile fracture strain | 23℃23℃ | ISO 527-2/50 | 9 | % |
| Tensile strain | Yield,23℃ | ISO 527-2/50 | 3.7 | % |
| tensile strength | Yield,23℃ | ISO 527-2/50 | 70 | Mpa |
| Tensile modulus | 23℃23℃ | ISO 527-1-2 | 3600 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357-3 | 222 | °C | |
| Hot deformation temperature | 1.8 MPa,Unannealed | ISO 75-2/A | 70 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD:260℃,2.0 mmAcross Flow : 500°F, 0,0787 in 33 | ISO 2577 | 1.1 | % |
| density | 23°C | ISO 1183 | 1.35 | g/cm³ |
| Shrinkage rate | MD:120℃,2.0 mm,4 hrsFlow : 248°F, 4 hr, 0.0787 in 44 | ISO 2577 | 0.4 | % |
| MD:260℃,2.0 mmFlow : 500°F, 0,0787 in 33 | ISO 2577 | 1.1 | % | |
| TD:120℃,2.0 mm,4 hrsAcross Flow : 248°F, 4 hr, 0,0787 in 44 | ISO 2577 | 0.4 | % | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.50 mm | UL 94 | V-0 | |
| 2.00 mm | UL 94 | 5VA | ||
| 3.00 mm | UL 94 | 5VA | ||
| 0.75 mm | UL 94 | V-0 | ||
| 0.40 mm | UL 94 | V-0 | ||
| Glow wire combustion index (GWFI) | 0.80 mm0.8 mm | IEC 60695-2-12 | 960 | °C |
| 1.5 mm1.5 mm | IEC 60695-2-12 | 960 | °C | |
| 3.0 mm3.0 mm | IEC 60695-2-12 | 960 | °C | |
| Ignition temperature of heating wire | 0.75 mm0.75 mm | IEC 60695-2-13 | 825 | °C |
| 1.5 mm1.5 mm | IEC 60695-2-13 | 825 | °C | |
| 3 mm3.0 mm | IEC 60695-2-13 | 800 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.