Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ASTM D955 | 1.0 % | |
ASTM D955 | 0.80 % | ||
density | ASTM D792 | 1.49 g/cm³ |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Suspended wall beam without notch impact strength | ISO 180 | 20 kJ/m² | |
Impact strength of cantilever beam gap | ISO 180/A | 3.5 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
elongation | Break | ASTM D638 | 2.5 % |
tensile strength | Yield | ASTM D638 | 60.0 MPa |
Tensile modulus | ASTM D638 | 6000 MPa |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI | UL 746 | 130 °C | |
RTI Imp | UL 746 | 130 °C | |
RTI Elec | UL 746 | 130 °C | |
vicat | ASTM D15252 | 235 °C | |
Heat distortion temperature | ASTM D648A | 160 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.