PC 3412R GY7D231 SABIC INNOVATIVE NANSHA
18
Form:Granules | Grade:Injection grade
Properties:
Flame retardantenhanceGlass fiber reinforced
Typical Applications:
Automotive sector
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Automotive sector |
| Properties: | Flame retardant | enhance | Glass fiber reinforced |
Certificates

Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | ASTM D-570 | 0.16 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23°C | ASTM D-256 | 107 | J/m |
| elongation | Break | ASTM D-638 | 5 | % |
| Rockwell hardness | ASTM D-785 | 122 | ||
| tensile strength | ASTM D-638 | 110 | Mpa | |
| bending strength | ASTM D-790 | 131 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Long term use temperature | UL 746B | 130 | °C | |
| Vicat softening temperature | ASTM D-1525 | 165 | °C | |
| Linear coefficient of thermal expansion | ASTM E-831 | 2.7×10 | 1/°C | |
| Hot deformation temperature | 1.8MPa | ASTM D-648 | 146 | °C |
| 0.45MPa | ASTM D-648 | 148 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| enhance | 20 | % | ||
| Bending modulus | ASTM D-790 | 5512 | Mpa | |
| Shrinkage rate | 3.2mm | ASTM D-955 | 1-3 | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D-257 | 1.0×10 | Ω.cm | |
| Dielectric constant | 60Hz | ASTM D-150 | 3.17 | |
| Dissipation factor | 60Hz | ASTM D-150 | 0.0009 | |
| Dielectric constant | 1MHz | ASTM D-150 | 3.13 | |
| Dissipation factor | 1MHz | ASTM D-150 | 0.0073 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.