PBT SK615SF NC010 DUPONT USA
64
Form:Granules | Grade:Injection grade
Properties:
Low viscosityHigh mobilityFiller: Glass fiber reinf30%Filler by weight
Typical Applications:
Electronic and electrical componentsAutomotive Applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electronic and electrical components | Automotive Applications |
| Properties: | Low viscosity | High mobility | Filler: Glass fiber reinf | 30% | Filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 57 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| FMVSS flammability | FMVSS302 | DNI | ||
| UL flame retardant rating | 1.5mm | IEC 60695-11-10,-20 | V-0 | |
| 0.75mm | IEC 60695-11-10,-20 | V-0 | ||
| 1.5mm | UL 94 | V-0 | ||
| 0.75mm | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break | ISO 527-2 | 2.2 | % |
| tensile strength | Break | ISO 527-2 | 154 | Mpa |
| Tensile modulus | ISO 527-2 | 11600 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357-3 | 222 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 210 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ISO 294-4 | 0.30 | % |
| TD | ISO 294-4 | 1.1 | % | |
| Top out temperature | 170 | °C | ||
| MediumDensity | 1.46 | g/cm³ | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | 0.750mm | UL 746 | PLC 3 | |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.