PC/PBT HCB9230 KUMHO KOREA
256
Form:Granules | Grade:Injection grade
Properties:
heat-resistingHigh impact resistance
Typical Applications:
CastersBumperElectronic fieldElectrical fieldElectrical/Electronic ApplicationsApplication in the automotive fieldElectrical components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Casters | Bumper | Electronic field | Electrical field | Electrical/Electronic Applications | Application in the automotive field | Electrical components |
| Properties: | heat-resisting | High impact resistance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179 | 无断裂 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | --2 | ISO 178 | 2100 | Mpa |
| -- | ASTM D790 | 2200 | Mpa | |
| elongation | Break | ASTM D638 | 120 | % |
| tensile strength | -- | ISO 527-2/50 | 56.0 | Mpa |
| -- | ASTM D638 | 63.0 | Mpa | |
| bending strength | --2 | ISO 178 | 80.0 | Mpa |
| -- | ASTM D790 | 87.0 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ISO 306/B50 | 115 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed3 | ISO 75-2/A | 98.0 | °C |
| 1.8MPa,Unannealed | ASTM D648 | 107 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | -- | ISO 294-4 | 0.60-0.90 | % |
| MD | ASTM D955 | 0.60-0.90 | % | |
| melt mass-flow rate | 250°C/5.0kg | ISO 1133 | 15 | g/10min |
| 250°C/5.0kg | ASTM D1238 | 13 | g/10min | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.