PC/ABS FR3023 901510 COVESTRO SHANGHAI
119
Form:Granules | Grade:Injection grade
Properties:
High mobilityFlame retardantEasy to process
Typical Applications:
Electrical applicationshousehold electrical appliancesAutomotive Applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical applications | household electrical appliances | Automotive Applications |
| Properties: | High mobility | Flame retardant | Easy to process |
Certificates
No Data...
Technical Data Sheet
| Filling analysis | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Melt viscosity | 260°C | ISO 11443-A | 220 | Pa·s |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Suspended wall beam without notch impact strength | 23°C | ISO 180 | 52 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning wire flammability index | 1.0 mm | IEC 60695-2-12 | 850 | °C |
| UL flame retardant rating | 1.2 mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break, 23°C | ISO 527-2/50 | 6.0 | % |
| Yield, 23°C | ISO 527-2/50 | 3.2 | % | |
| tensile strength | Break, 23°C | ISO 527-2/50 | 48.0 | Mpa |
| Yield, 23°C | ISO 527-2/50 | 62.0 | Mpa | |
| Tensile modulus | 23°C | ISO 527-2/1 | 5400 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | -- | ISO 306/B120 | 102 | °C |
| -- | ISO 306/B50 | 99.0 | °C | |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 88.0 | °C |
| 0.45 MPa, Unannealed | ISO 75-2/B | 96.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 0.20 | % |
| Saturation, 23°C | ISO 62 | 0.50 | % | |
| Shrinkage rate | Flow | ISO 2577 | 0.20 - 0.30 | % |
| 横向Flow | ISO 2577 | 0.20 - 0.30 | % | |
| Melt Volume Flow Rate (MVR) | 260°C/5.0 kg | ISO 1133 | 24.0 | cm3/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | 23°C | IEC 60093 | 1.0E+17 | ohms·cm |
| Surface resistivity | IEC 60093 | 1.0E+16 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.