Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1.14 g/cm³ | |
Shrinkage rate | ISO 294-4 | 1.6 % | |
ISO 294-4 | 1.4 % | ||
Water absorption rate | ISO 62 | 1.2 % | |
ISO 62 | 2.4 % | ||
Outdoor applicability | UL 746C | f2 |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Hot filament ignition temperature | IEC 60695-2-13 | 825 °C | |
IEC 60695-2-13 | 850 °C | ||
IEC 60695-2-13 | 850 °C | ||
IEC 60695-2-13 | 850 °C | ||
Limiting Oxygen Index | ISO 4589-2 | 26 % | |
Burning wire flammability index | IEC 60695-2-12 | 960 °C | |
UL flame retardant rating | UL 94 | V-2 | |
UL 94 | V-2 | ||
UL 94 | V-2 | ||
UL 94 | V-2 | ||
Burning wire flammability index | IEC 60695-2-12 | 960 °C | |
IEC 60695-2-12 | 960 °C | ||
IEC 60695-2-12 | 960 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ISO 527-2 | 75.0 MPa | |
Tensile strain | ISO 527-2 | 5.0 % | |
Nominal tensile fracture strain | ISO 527-2 | 13 % | |
Flexural modulus | ISO 178 | 3200 MPa | |
bending strength | ISO 178 | 100 MPa | |
Poisson's ratio | ISO 527-2 | 0.40 | |
Tensile modulus | ISO 527-2 | 3800 MPa | |
tensile strength | ISO 527-2 | 95.0 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
Impact strength of cantilever beam gap | ISO 180 | 5.0 kJ/m² | |
ISO 180 | 6.0 kJ/m² | ||
Charpy Notched Impact Strength | ISO 179/1eA | 5.0 kJ/m² | |
ISO 179/1eA | 6.0 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
High arc combustion index (HAI) | UL 746 | PLC 0 | |
UL 746 | PLC 0 | ||
High Voltage Arc Traceability Rate (HVTR) | UL 746 | PLC 0 | |
Hot wire ignition (HWI) | UL 746 | PLC 4 | |
Volume resistivity | IEC 60093 | 1E+13 ohms·cm | |
dielectric strength | IEC 60243 | 26 kV/mm | |
arc resistance | ASTM D495 | PLC 5 | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 | |
High arc combustion index (HAI) | UL 746 | PLC 1 | |
UL 746 | PLC 0 | ||
Hot wire ignition (HWI) | UL 746 | PLC 4 | |
UL 746 | PLC 3 | ||
UL 746 | PLC 2 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO 11359-2 | 1E-04 cm/cm/°C | ||
RTI Elec | UL 746 | 130 °C | |
UL 746 | 130 °C | ||
UL 746 | 130 °C | ||
UL 746 | 130 °C | ||
RTI Imp | UL 746 | 75.0 °C | |
Hot deformation temperature (HDT) | ISO 75-2/B | 230 °C | |
ISO 75-2/A | 90.0 °C | ||
melting temperature | ISO 11357-3 | 260 °C | |
ISO 11359-2 | 1E-04 cm/cm/°C | ||
RTI Imp | UL 746 | 75.0 °C | |
UL 746 | 75.0 °C | ||
UL 746 | 75.0 °C | ||
RTI Str | UL 746 | 75.0 °C | |
UL 746 | 85.0 °C | ||
UL 746 | 85.0 °C | ||
UL 746 | 85.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.