PP Copolymer Tecolen® CP20 GR40 NL

0
  • Properties:
    Filler
    glass fiber reinforced material
    40%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO11831.20 g/cm³
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94HB
UL flame retardant ratingUL94HB
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO527-27000 MPa
Tensile stressISO527-280.0 MPa
Tensile strainISO527-25.0 %
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapISO180/1A15 kJ/m²
Impact strength of cantilever beam gapISO180/1A25 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC600931E+15 ohms
Volume resistivityIEC600931E+15 ohms·cm
Thermal performanceTest ConditionTest MethodTest Result
ISO75-2/A140 °C
melting temperatureISO11357-3160到165 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.