- Properties:Filler carbon fiber reinforced material 15% filler by weight
- Usages:Textile applications medical nursing supplies business equipment automotive applications engineering accessories
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 20 kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | ISO 527-2 | 15000 MPa | |
| tensile strength | Break | ISO 527-2 | 145 MPa |
| Tensile strain | Yield | ISO 527-2 | 1.1 % |
| Bending modulus | ISO 178 | 13000 MPa | |
| bending strength | ISO 178 | 205 MPa | |
| Friction coefficient | Dynamic | 0.18 | |
| Static | 0.21 | ||
| Bending strain | ISO 178 | 1.5 % |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Maximum operating temperature | ShortTerm | 240 °C | |
| Continuous use temperature | UL 746B | 220 °C | |
| Vicat softening temperature | ISO 306/A | 240 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ISO 1183 | 1.44 g/cm³ | |
| Shrinkage rate | DIN 16901 | 0.10to0.30 % | |
| Water absorption rate | 23°C,24hr | <0.050 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Surface resistivity | IEC 60093 | <1.0E+4 ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.