PA12 LV-2H EMS-CHEMIE SWITZERLAND
55
Form:Granules | Grade:Extrusion grade
Properties:
Impact modificationHigh impact resistanceHydrolysis resistance
Typical Applications:
sporting goodsAutomotive sectorElectrical fieldElectronic fieldHome appliance componentspowerTool productsHousehold goodsConsumer goods sectorEngineering accessoriesPneumatic applicationsHydraulic applicationsIndustrial applicationsMedical devices
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | sporting goods | Automotive sector | Electrical field | Electronic field | Home appliance components | power | Tool products | Household goods | Consumer goods sector | Engineering accessories | Pneumatic applications | Hydraulic applications | Industrial applications | Medical devices |
| Properties: | Impact modification | High impact resistance | Hydrolysis resistance |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Shore hardness | cond | ISO 2039-1 | 74 | Mpa |
| Tensile modulus | 1mm/min,cond | ISO 527 | 4400 | Mpa |
| Impact strength of cantilever beam gap | Charpy,-30℃,dry(cond) | ISO 179/1eA | 15 | KJ/m |
| tensile strength | 5mm/min,cond,Break | ISO 527 | 90 | Mpa |
| Tensile modulus | ASTM D412/ISO 527 | 4400(MPa) | kg/cm²(MPa)[Lb/in²] | |
| Elongation at Break | 5mm/min,cond | ISO 527 | 10 | % |
| Impact strength of cantilever beam gap | Charpy,23℃,cond | ISO 179/1eU | 70 | KJ/m |
| Charpy,23℃,cond | ISO 179/1eA | 20 | KJ/m | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Maximum operating temperature | long term,dry | ISO 2578 | 0.3 | °C |
| Melting temperature | dry | ISO 11357 | 178 | °C |
| Maximum operating temperature | short term,dry | ISO 2578 | 1.5 | °C |
| Hot deformation temperature | 1.80MPa,dry | ISO 75 | 80 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.