PP Polifor® L6 GF/30 NATURALE SO.F.TER ITALY
Properties:
Filler glass fiber reinforced material 30% filler by weight
Typical Applications:
Shield application in the automotive field
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Shield | application in the automotive field |
| Properties: | Filler | glass fiber reinforced material | 30% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 100 | J/m |
| 0°C | ASTM D256 | 90 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Extreme Oxygen Index | ASTM D2863 | 21 | % | |
| Hot filament ignition temperature | IEC 60695-2-13 | 650 | °C | |
| UL flame retardant rating | 3.2mm | UL 94 | HB | |
| 1.6mm | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ASTM D790 | 5500 | MPa | |
| elongation | Break | ASTM D638 | 3.0 | % |
| tensile strength | Yield | ASTM D638 | 85.0 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | 125°C | IEC 335 | Pass | |
| Vicat softening temperature | ASTM D15252 | 135 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 150 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | Internal Method | 0.30 | % | |
| melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 2.5 | g/10min |
| density | ASTM D792 | 1.13 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.