Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO62 | 1.1 % |
flammability | Test Condition | Test Method | Test Result |
---|
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 700 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 700 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 700 °C |
Limiting Oxygen Index | | ISO4589-2 | 36 % |
FrenchFireIndex | | NFF16-101 | F2 |
FrenchSmokeIndex | | NFF16-101 | I2 |
UL flame retardant rating | | UL94 | V-0 |
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
EuropeanRailwaysCertifications | | EN45545-2 | HL3 |
EuropeanRailwaysCertifications | | EN45545-2 | HL3 |
EuropeanRailwaysCertifications | | EN45545-2 | HL3 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2/1A | 3500 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | 1E+15 ohms |
Volume resistivity | | IEC60093 | 1E+15 ohms·cm |
dielectric strength | | IEC60243-1 | 34 KV/mm |
| | IEC60250 | 3.50 |
Dissipation Factor | | IEC60250 | 0.020 |
CTI | | IEC60112 | 600 V |
CTI | | IEC60112 | 475 V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.