PA6 C 50H2 SOLVAY FRANCE
138
Form:Granules | Grade:Injection grade
Typical Applications:
Laptop case
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Laptop case |
Certificates
No Data...
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Burning wire flammability index | 0.8mm | IEC 60695-2-12 | 960 | °C |
| UL flame retardant rating | 0.40mm | UL 94 | V-0 | |
| smoke density | NFF16-101 | I2 | ||
| UL flame retardant rating | NFF16-101 | F2 | ||
| Extreme Oxygen Index | ISO 4589-2 | 36 | % | |
| Hot filament ignition temperature | 3.2mm | IEC 60695-2-13 | 700 | °C |
| 1.6mm | IEC 60695-2-13 | 700 | °C | |
| 0.8mm | IEC 60695-2-13 | 700 | °C | |
| Burning wire flammability index | 3.2mm | IEC 60695-2-12 | 960 | °C |
| 1.6mm | IEC 60695-2-12 | 960 | °C | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C | ISO 527-2/1A | 3500 | Mpa |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C,24hr | ISO 62 | 1.1 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | SolutionB | IEC 60112 | PLC 1 | |
| SolutionA | IEC 60112 | PLC 0 | ||
| Dissipation factor | IEC 60250 | 0.020 | ||
| Relative permittivity | IEC 60250 | 3.50 | ||
| Dielectric strength | 2.00mm | IEC 60243-1 | 34 | KV/mm |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+15 | ohms | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| EuropeanRailwaysCertifications | R25 | EN45545-2 | HL3 | |
| R23 | EN45545-2 | HL3 | ||
| R22 | EN45545-2 | HL3 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.