physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183 | 1.77 g/cm³ |
Shrinkage rate | | ISO 294-4 | 0.90 % |
Shrinkage rate | | ISO 294-4 | 0.30 % |
Water absorption rate | | ISO 62 | 1.4 % |
flammability | Test Condition | Test Method | Test Result |
---|
Flammability level | | UL 94 | V-0 |
Flammability level | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 15000 Mpa |
Tensile modulus | | ISO 527-2 | 9500 Mpa |
Tensile modulus | | ISO 527-2 | 6500 Mpa |
tensile strength | | ISO 527-2 | 190 Mpa |
tensile strength | | ISO 527-2 | 100 Mpa |
tensile strength | | ISO 527-2 | 85.0 Mpa |
Tensile strain | | ISO 527-2 | 1.7 % |
Tensile strain | | ISO 527-2 | 3.0 % |
Tensile strain | | ISO 527-2 | 3.0 % |
Flexural modulus | | ISO 178 | 13000 Mpa |
Flexural modulus | | ISO 178 | 8500 Mpa |
Flexural modulus | | ISO 178 | 5500 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA | 14 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 13 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 40 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 50 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | 15 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | 15 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | IEC 60093 | > 1.0E+15 ohms·cm |
dielectric strength | | IEC 60243-1 | 30 KV/mm |
relative permittivity | | IEC 60250 | 4.30 |
relative permittivity | | IEC 60250 | 4.00 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 2 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/B | 290 °C |
Heat distortion temperature | | ISO 75-2/A | 290 °C |
melting temperature | | ISO 11357-3 | 295 °C |
Linear coefficient of thermal expansion | | ASTM D696 | 2.0E-5 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 1.7E-5 cm/cm/°C |
Linear coefficient of thermal expansion | | ASTM D696 | 4.5E-5 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 6.5E-5 cm/cm/°C |
RTI Elec | | UL 746 | 130 °C |
Thermal Index - 5000 hr | | IEC 60216 | 163 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.