Share
Add to compare

PET AV2 370 HF DSM Additive Manufacturing

Properties:
Filler glass fiber reinforced material 35% filler by weight
Typical Applications:
Valves valve components
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Valves | valve components
Properties:Filler | glass fiber reinforced material | 35% | filler by weight

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 179/1eU60kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA9.5kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU60kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA9.5kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating1.5mmIEC 60695-11-10,-20HB
UL flame retardant rating0.75mmIEC 60695-11-10,-20HB
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusISO 527-213000MPa
tensile strengthBreakISO 527-2200MPa
Tensile strainBreakISO 527-22.5%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Linear coefficient of thermal expansionTDISO 11359-24E-05cm/cm/°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B250°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A235°C
Melting temperatureISO 11357-3255°C
Linear coefficient of thermal expansionMDISO 11359-22.5E-05cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 11831.66g/cm³
Water absorption rateSaturation,23°CISO 620.45%
Water absorption rateEquilibrium,23°C,50%RHISO 620.18%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Volume resistivityIEC 60093>1.0E+15ohms·cm
Dielectric strengthIEC 60243-133kV/mm
Relative permittivity100HzIEC 602503.70
Relative permittivity1MHzIEC 602503.50
Dissipation factor100HzIEC 602503E-03
Dissipation factor1MHzIEC 602500.013
Compared to the anti leakage trace indexIEC 60112PLC 2
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.