PVC Trovidur® EA R?chling Engineering Plastics SE & Co. KG
Typical Applications:
Building application field building materials
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Building application field | building materials |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179 | 4.0 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break | ISO 527-2 | 15 | % |
| Tensile modulus | ISO 527-2 | 3200 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| thermal conductivity | DIN 52612 | 0.16 | W/m/K | |
| Linear coefficient of thermal expansion | MD | DIN 53752 | 6.0E-5到8.0E-5 | cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.47 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 1MHz | IEC 60250 | 0.020 | |
| Dielectric constant | IEC 60250 | 3.20 | ||
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | >1.0E+13 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.