PA6T Grivory® GV-4H BK 9915 EMS-CHEMIE SUZHOU
199
- Properties:Glass fiber reinforcedThermal stability
- Usages:household electrical appliances
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ISO 62 | 4.5 % | |
Shrinkage rate | ISO 294-4 | 0.60 % | |
ISO 294-4 | 0.10 % |
other | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2/1 | 13000 Mpa | |
tensile strength | ISO 527-2/5 | 210 Mpa | |
Tensile strain | ISO 527-2/5 | 3.0 % | |
Charpy Notched Impact Strength | ISO 179/1eA | 13 kJ/m² | |
ISO 179/1eU | 90 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC 60093 | 1E+13 ohms | |
Volume resistivity | IEC 60093 | 1E+14 ohms*cm | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 | |
dielectric strength | IEC 60246-1 | 33 KV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/A | 235 °C | |
ISO 75-2/C | 145 °C | ||
Linear coefficient of thermal expansion | ISO 11359-2 | 0.000015 cm/cm/ ℃ | |
ISO 11359-2 | 0.000090 cm/cm/ ℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top