PA4T F11 DSM HOLAND
Form:Granules | Grade:Injection grade
Properties:
Thermal stabilityFlame retardant
Typical Applications:
Electronic and electrical components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electronic and electrical components |
| Properties: | Thermal stability | Flame retardant |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 50 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | UL 94 | V-0 | ||
| UL 94 | V-0 | |||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ISO 178 | 245 | Mpa | |
| Bending modulus | ISO 178 | 11500 | Mpa | |
| Tensile strain | Break, 160°C | ISO 527-2 | 3.7 | % |
| Break, 120°C | ISO 527-2 | 2.7 | % | |
| Break | ISO 527-2 | 2.0 | % | |
| tensile strength | Break, 160°C | ISO 527-2 | 70.0 | Mpa |
| Break, 120°C | ISO 527-2 | 100 | Mpa | |
| Break | ISO 527-2 | 155 | Mpa | |
| Tensile modulus | 160°C | ISO 527-2 | 5000 | Mpa |
| 120°C | ISO 527-2 | 7500 | Mpa | |
| -- | ISO 527-2 | 12000 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Thermal Index - 5000 hr | IEC 60216 | 163 | °C | |
| RTI Elec | 0.35 mm | UL 746 | 140 | °C |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 3.5E-5 7.0E-5 | cm/cm/°C |
| Flow | ISO 11359-2 | 1.5E-5 3.0E-5 | cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 325 | °C | |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 305 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 1.6 | % |
| Shrinkage rate | Flow | ISO 294-4 | 0.30 | % |
| 横向Flow | ISO 294-4 | 1.2 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Relative permittivity | 1 MHz | IEC 60250 | 3.90 | |
| 100 Hz | IEC 60250 | 4.20 | ||
| Dielectric strength | IEC 60243-1 | 33 | KV/mm | |
| Volume resistivity | IEC 60093 | > 1.0E+15 | ohms·cm | |
| Relative permittivity | 1.00 GHz | IEC 60250 | 3.90 | |
| 10.0 GHz | IEC 60250 | 3.90 | ||
| Compared to the anti leakage trace index | IEC 60112 | V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.