PA6 Tekumid 6 SC TEKUMA Kunststoff GmbH

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityg/cm³1.26 --
Water absorption rate%9.0to10 --
Water absorption rate%2.5to3.4 --
hardnessTest ConditionTest MethodTest Result
Rockwell hardness120 102
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingHB --
UL flame retardant ratingV-2 --
Hot filament ignition temperature°C750 --
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strength YieldMPa80.0 40.0
tensile strength BreakMPa60.0 30.0
elongationBreak%>60 >200
Flexural modulusMPa2800 800
bending strengthMPa120 60.0
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapJ/m45 500
Suspended wall beam without notch impact strengthJ/m50 600
Electrical performanceTest ConditionTest MethodTest Result
Surface Resistivityohms1E+13 1E+10
Volume resistivityohms·cm1E+15 1E+11
dielectric strengthkV/mm90 40
dielectric constant3.60 7.00
Dissipation Factor0.030 --
Thermal performanceTest ConditionTest MethodTest Result
thermal conductivityW/m/K0.25 --
Heat distortion temperature°C180 --
Heat distortion temperature°C70.0 --
vicat°C200 --
vicat°C165 --
melting temperature°C215to220 --
Linear coefficient of thermal expansioncm/cm/°C7.5E-05 --
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.