Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Apparent density | | | 0.70 g/cm³ |
Molten Volume Flow Rate (MVR) | | ISO 1133 | 40.0 cm3/10min |
Water absorption rate | | ISO 62 | 5.2 到 5.8 % |
Water absorption rate | | ISO 62 | 1.5 到 1.9 % |
viscosity number | | ISO 307 | 145 cm³/g |
Mold Shrinkage - Constrained 3 | | | 0.55 % |
flammability | Test Condition | Test Method | Test Result |
---|
Flammability level | | IEC 60695-11-10, -20 | HB |
Polymer Abbreviation | | | PA66-GF30 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 10000 Mpa |
Tensile stress | | ISO 527-2 | 190 Mpa |
Tensile strain | | ISO 527-2 | 3.0 % |
Tensile creep modulus | | ISO 899-1 | -- Mpa |
Flexural modulus | | ISO 178 | 8600 Mpa |
Bending stress | | ISO 178 | 280 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO 179/1eU | 70 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 85 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC 60093 | -- ohms |
Volume resistivity | | IEC 60093 | 1.0E+15 ohms·cm |
| | IEC 60250 | 3.50 |
Dissipation Factor | | IEC 60250 | 0.014 |
CTI | | IEC 60112 | 550 V |
injection | Test Condition | Test Method | Test Result |
---|
Processing (melt) temperature | | | 280 到 300 °C |
Temperature | | | 80 到 90 °C |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO 75-2/B | 250 °C |
| | ISO 75-2/A | 250 °C |
melting temperature | | ISO 11357-3 | 260 °C |
specific heat | | | 1500 J/kg/°C |
thermal conductivity | | DIN 52612 | 0.35 W/m/K |
温度指数 - at 50% loss of tensile strength | | IEC 60216 | 165 °C |
温度指数 - at 50% loss of tensile strength | | IEC 60216 | 135 °C |
Maximum operating temperature - short cycle operation | | | 240 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.