PC L-1250Y BK TEIJIN SINGAPORE
87
Form:Granules | Grade:Injection grade
Properties:
transparentMedium viscosityHigh mobility
Typical Applications:
Industrial componentsHousehold appliancesMechanical componentsCastersLabor protection equipmentNursing supplies
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Industrial components | Household appliances | Mechanical components | Casters | Labor protection equipment | Nursing supplies |
| Properties: | transparent | Medium viscosity | High mobility |
Certificates

Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Refractive index | ASTM D542 | 1.585 | ||
| transmissivity | 3000 μm | ASTM D1003 | 88.0 | % |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of simply supported beam without notch | ISO 179 | 无断裂 | ||
| Charpy Notched Impact Strength | ISO 179 | 76 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.5 mm | UL 94 | HB | |
| 0.40 mm | UL 94 | V-2 | ||
| Burning wire flammability index | 1.5 mm | IEC 60695-2-12 | 825 | °C |
| 3.0 mm | IEC 60695-2-12 | 875 | °C | |
| Hot filament ignition temperature | 1.5 mm | IEC 60695-2-13 | 850 | °C |
| 3.0 mm | IEC 60695-2-13 | 850 | °C | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ISO 178 | 93.0 | Mpa | |
| Bending modulus | ISO 178 | 2350 | Mpa | |
| Nominal tensile fracture strain | ISO 527-2/50 | > 50 | % | |
| Tensile strain | Yield | ISO 527-2/50 | 6.0 | % |
| tensile strength | Yield | ISO 527-2/50 | 61.0 | Mpa |
| Tensile modulus | ISO 527-2/1 | 2400 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI | 0.75 mm | UL 746 | 125 | °C |
| RTI Imp | 0.75 mm | UL 746 | 115 | °C |
| RTI Elec | 0.75 mm | UL 746 | 125 | °C |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 7.0E-5 | cm/cm/°C |
| Flow | ISO 11359-2 | 7.0E-5 | cm/cm/°C | |
| Vicat softening temperature | ISO 306/B50 | 149 | °C | |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 129 | °C |
| 0.45 MPa, Unannealed | ISO 75-2/B | 142 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 24 hr, 23°C | ISO 62 | 0.20 | % |
| Shrinkage rate | Flow : 4.00 mm | Internal Method | 0.50 - 0.70 | % |
| 横向Flow : 4.00 mm | Internal Method | 0.50 - 0.70 | % | |
| Melt Volume Flow Rate (MVR) | 300°C/1.2 kg | ISO 1133 | 8.00 | cm3/10min |
| density | ISO 1183 | 1.20 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Relative permittivity | 100 Hz | IEC 60250 | 3.10 | |
| 1 MHz | IEC 60250 | 3.00 | ||
| Dissipation factor | 100 Hz | IEC 60250 | 1.0E-3 | |
| 1 MHz | IEC 60250 | 9.0E-3 | ||
| Dielectric strength | IEC 60243-1 | 30 | KV/mm | |
| Volume resistivity | IEC 60093 | > 1.0E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | > 1.0E+15 | ohms | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 2 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.