ABS VF512 DAICEL JAPAN
23
Form:Granules | Grade:Flame retardant grade
Properties:
Flame retardant
Typical Applications:
Home appliance components
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Home appliance components |
| Properties: | Flame retardant |
Certificates

Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| melt mass-flow rate | 220℃,10kg | ISO 1133 | 33 | g/10min |
| Water absorption rate | ISO 62 | 0.3 | % | |
| density | ISO 1183 | 1.10 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Charpy Notched Impact Strength | 23℃ | ISO 179/1eA | 18 | KJ/m |
| -30℃ | ISO 179/1eA | 9 | KJ/m | |
| Impact strength of cantilever beam gap | 23℃,6.4mm | ASTM D-256 | 180 | J/m |
| -30℃,6.4mm | ASTM D-256 | 80 | J/m | |
| Rockwell hardness | ISO 2039 | R112 | ||
| tensile strength | ISO 527 | 46 | Mpa | |
| bending strength | ISO 178 | 78 | Mpa | |
| Bending modulus | ISO 178 | 2500 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.80MPa,12.7mm | ISO 75/A | 73 | °C |
| 1.82MPa,12.7mm | ASTM D-648 | 85 | °C | |
| Vicat softening temperature | 50N,50℃/h | ISO 306/B50 | 83 | °C |
| 9.8N,50℃/h | ASTM D-1525 | 93 | °C | |
| Ball indentation temperature | 80 | °C | ||
| Linear coefficient of thermal expansion | Flow | ISO 11359 | 8 | ×10 |
| Combustibility | UL 94 | V-2 | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | ASTM D-955 | 0.4-0.6 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | 1.5mm | ASTM D-149 | 33 | MV/m |
| Arc resistance | 3.0mm | ASTM D-495 | 36 | sec |
| 3.0mm | ASTM D-495 | PLC_7 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.