Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.58到1.63 g/cm³ |
Ash Content | | ISO3451 | 28.0到34.0 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Break | ASTMD638 | 105 MPa |
elongation | Break | ASTMD638 | 1.8 % |
Flexural modulus | | ASTMD790 | 8000 MPa |
bending strength | | ASTMD790 | 165 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256 | 7.50 kJ/m² |
Suspended wall beam without notch impact strength | | ASTMD256 | 55.0 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | ASTMD257 | 1E+16 ohms·cm |
dielectric strength | | ASTMD149 | 18 kV/mm |
dielectric constant | | ASTMD150 | 3.40 |
Dissipation Factor | | ASTMD150 | 0.020 |
Dissipation Factor | | ASTMD150 | 0.020 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat Deflection Temperature | | ASTMD648 | 200 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.